Analisa Relay Jarak Pada Saluran Transmisi 150 Kv Pada Gardu Induk Sekarputih Ke Gardu Induk Balongbendo
Abstract
In the electric power system it does not always run normally. There are many disturbances or disturbance anomalies that can disrupt the operation of the system. One of them is at the Sekarputih main substation. last two years, the channel has experienced five short- circuit disruptions. As a result, electromagnetic distance relays must be replaced with digital distance relays equipped with reclosers. The reclosers will function when there is a relay disturbance on a trip and automatically reconnect. The disruptions may occur due to damage brought by unstable weather conditions. Indirectly, the value of relay settings will change and deviate from the PLN (state electricity company) standards. Therefore, relay re-setting was performed using two methods: the Fuzzy Mamdhani and the ANFIS methods. Using the Fuzzy Mamdhani method, the relay distance settings were as follows: Zone 1 = 0.523 Ω, Zone 2 = 0.54 Ω, and Zone 3 = 1.58 Ω. Meanwhile, the relay distance settings by the ANFIS method were: Zone 1 = 0.432 Ω, Zone 2 = 0.65 Ω, and Zone 3 = 1.22 Ω. The previous values of relay distance settings by PLN were Zone 1 = 0.587 Ω, Zone 2 = 1.046 Ω, and Zone 3 = 1.766 Ω.
Downloads
References
Y. Maula, “Analisa Relay Jarak Pada Saluran Transmisi 150KV Gardu Induk Bangil ke Gardu Induk Lawang,” pp. 219–224, 2021.
M. M. Almomani and S. F. Algharaibeh, “Modelling and Testing of a Numerical Pilot Distance Relay for Compensated Transmission Lines,” Int. J. Sci. Res. Eng. Dev., vol. 3, no. December, pp. 776–786, 2020.
I. N. Ifan, “Analisa Koordinasi Proteksi Relay Jarak Dengan Software Digsilent Pada Gi Sukolilo Ke Gi Kenjeran Menggunakan Metode Fuzzy,” BEES Bull. Electr. Electron. Eng., vol. 3, no. 1, pp. 14–22, 2022, [Online]. Available: https://ejurnal.seminar-id.com/index.php/bees/article/view/3150
M. R. Javed, U. S. Virk, A. Waleed, and M. Y. Jamal, “The performance comparison of artificial intelligence based distance relays for the protection of transmission lines,” Bull. Electr. Eng. Informatics, vol. 11, no. 3, pp. 1177–1185, 2022, doi: 10.11591/eei.v11i3.3305.
R. A. Wahyuningsih, A. B. Muljono, and S. Supriyatna, “Proteksi Rele Jarak (Distance Relay) Pada Saluran Udara Tegangan Tinggi (Sutt) 150 Kv Sistem Kelistrikan Lombok,” Dielektrika, vol. 7, no. 1, pp. 15–24, 2020, [Online]. Available: http://dielektrika.unram.ac.id/index.php/dielektrika/article/view/230
A. Srinaldi, Muliadi, Syukri, M. R. Azmi, and Husaini, “Proteksi Jaringan Transmisi Saluran Udara dengan Menggunakan Relay Jarak,” Aceh J. Electr. Eng. Technol., vol. 1, no. 1, pp. 6–11, 2021.
A. D. Suryadipraja, “STUDI ANALISA KERJA RELE JARAK PADA SALURAN TRANSMISI GARDU INDUK WONOSARI-GARDU INDUK SOLO BARU 150 kV,” pp. 1–12, 2018.
B. Dhinar and A. Devi, “Evaluasi Kinerja Relai Jarak Saluran Udara Tegangan Tinggi 150 Kv Di Gardu Induk Citra Habitat – Tigaraksa,” 2021.
T. Ridzwansyah and T. Wati, “Studi Koordinasi Proteksi pada Sistem Kelistrikan di PT . Terminal Teluk Lamong Menggunakan Metode Neural Network,” Semin. Nas. Sains dan Teknol. Terap. X, pp. 1–7, 2022.
M. A. Alawan, “Design of intelligent distance relay for cascaded transmission lines fault detection based on fuzzy logic system,” Period. Eng. Nat. Sci., vol. 8, no. 2, pp. 1075–1082, 2020.
D. Eko Rofianto, E. Arfah Zuliari, and T. Wati, “Analisa Perencanaan Pemasangan Differential Relay Pada PT.Bramindo Niaga Pratama,” Semin. Nas. Sains dan Teknol. Terap. VII - Inst. Teknol. Adhi Tama Surabaya, pp. 723–728, 2019.
M. F. Al-Kababjie, “A Fuzzy Logic Distance Relay,” Am. J. Electr. Power Energy Syst., vol. 3, no. 5, p. 95, 2014, doi: 10.11648/j.epes.20140305.12.
I. Eker and Y. Torun, “Fuzzy logic control to be conventional method,” Energy Convers. Manag., vol. 47, no. 4, pp. 377–394, 2006, doi: 10.1016/j.enconman.2005.05.008.
S. A. S. Al Kazzaz, I. Ismael, and K. K. Mohammed, “Fault detection and location of power transmission lines using intelligent distance relay,” Int. J. Power Electron. Drive Syst., vol. 11, no. 2, pp. 726–734, 2020, doi: 10.11591/ijpeds.v11.i2.pp726-734.
T. Hassan, “On-line trained adaptive neuro-fuzzy inference system for distance relay of transmission line protection,” Online J. Electron. …, no. January 2009, 2009, [Online]. Available: https://www.researchgate.net/profile/Tamer_Kamel/publication/239523806_On-Line_Trained_Adaptive_Neuro-Fuzzy_Inference_System_for_Distance_Relay_of_Transmission_line_Protection/links/53ebfd740cf24f241f1558be.pdf
M. Shadaei, M. A. Jarrahi, A. A. Bagheri, and H. Samet, “A comprehensive investigation on performance of distance relays in transmission lines connected to wind farms,” 2020 15th Int. Conf. Prot. Autom. Power Syst. IPAPS 2020, no. December, pp. 1–6, 2020, doi: 10.1109/IPAPS52181.2020.9375545.
V. H. Makwana and B. R. Bhalja, “A new digital distance relaying scheme for series-compensated double-circuit line during open conductor and ground fault,” IEEE Trans. Power Deliv., vol. 27, no. 2, pp. 910–917, 2012, doi: 10.1109/TPWRD.2011.2178438.
Bila bermanfaat silahkan share artikel ini
Berikan Komentar Anda terhadap artikel Analisa Relay Jarak Pada Saluran Transmisi 150 Kv Pada Gardu Induk Sekarputih Ke Gardu Induk Balongbendo
Pages: 133-141
Copyright (c) 2024 Trisna Wati, Wahyu Setyo Pambudi, Titiek Suheta, Ridho Gustianto Singgih Warsono

This work is licensed under a Creative Commons Attribution 4.0 International License.
Authors who publish with this journal agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under Creative Commons Attribution 4.0 International License that allows others to share the work with an acknowledgment of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgment of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (Refer to The Effect of Open Access).