Analisa Koordinasi Proteksi Relay Jarak Dengan Software Digsilent Pada Gi Sukolilo Ke Gi Kenjeran Menggunakan Metode Fuzzy
Abstract
The electromagnetic distance relay at the Sukolilo substation has been replaced with a digital relay equipped with a recloser. If there is a disturbance, the relay will trip and reconnect automatically. The setting values have changed as a result of this replacement. The purpose of this study was to determine the value of the distance relay setting at the Sukolilo substation using traditional calculations, which would then be implemented in a computer program developed by PLN Ltd. It also found out the results of calculations per zone included in the distance relay zone. This study employed a fuzzy method with digsilent software. The research data comprised data on SUTT installed at the Sukolilo substation, data on conductor relay settings at the Sukolilo substation, data on short circuit currents, and transformer ratios. The simulation results in this study indicated that the distance relay had a setting value that was not in accordance with the standard in the old setting of the Sukolilo substation zone 1 for protection (175.42%), while the calculation results showed that zone 1 protected 58.44%. The new impedance setting covered zone 1 = 0.338, zone 2 = 0.862, and zone 3 = 1.488, whereas the old impedance setting showed zone 1 = 0.1126, zone 2 = 0.2924, and zone 3 = 0.4128. The old setting time and the new setting showed a big difference in that the old setting time was 0.25 seconds with a range of 175.42% while the new setting time was 0.25 seconds with a range of 58.44%.
Downloads
References
H. Asman, H. Eteruddin, and . A., “Analisis Proteksi Rele Jarak Pada Saluran Transmisi 150 Kv Garuda Sakti – Pasir Putih Menggunakan Pscad,” SainETIn, vol. 2, no. 1, pp. 27–36, 2018, doi: 10.31849/sainetin.v2i1.1672.
Wahyu Hendra Prasetya, Misbahul Munir, N. P. U. Putra, Nasyith, H. Rohiem, and I. Masfufiah, “Analisa Koordinasi Proteksi Over Current Relay Pada Gardu Induk Bangil,” Pros. Semin. Nas. Sains dan Teknol. Terap., vol. 10, no. 2, pp. 1–15, 2018.
G. Sinus, “Studi Analisis Relai Jarak Jaringan Transmisi 150 kV Sungailiat - Air Anyir - Pangkalpinang,” vol. 8, no. 2, pp. 253–259, 2019.
H. Abibie and Sulistyowati, “Kajian Koordinasi Sistem Proteksi Pada Sistem Transmisi 70 kV GI Banaran Kediri Transmission Line Bay Pare,” ELPOSYS J. Sist. Kelistrikan, vol. 7, no. 3, pp. 51–57, 2020, doi: 10.33795/elposys.v7i3.21.
A. Ekaprasetyo and W. S. Pambudi, “Prototype Rancang Bangun Robot Penyiram Tanaman Otomatis Dengan Kendali Fuzzy,” J. Ilm. Matrik, vol. 22, no. 1, pp. 102–109, 2020, doi: 10.33557/jurnalmatrik.v22i1.846.
Bila bermanfaat silahkan share artikel ini
Berikan Komentar Anda terhadap artikel Analisa Koordinasi Proteksi Relay Jarak Dengan Software Digsilent Pada Gi Sukolilo Ke Gi Kenjeran Menggunakan Metode Fuzzy
Pages: 14-22
Copyright (c) 2023 Misbahul Munir, Novian Patria Uman Putra, Wahyu Setyo Pambudi, Nasyith Hananur Rohiem, Ipung Nur Ifan

This work is licensed under a Creative Commons Attribution 4.0 International License.
Authors who publish with this journal agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under Creative Commons Attribution 4.0 International License that allows others to share the work with an acknowledgment of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgment of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (Refer to The Effect of Open Access).