Abstract

Transformers are essential equipment in electric power transmission systems that function to adjust voltage levels according to system requirements. Over the course of operation, transformer performance may degrade due to aging, loading conditions, and the frequency of disturbances, which can potentially reduce the reliability of power supply. This study examined 22 units of 150 kV GIS-type power transformers with a capacity of 60 MVA located across 8 GIS substations, using a Health Index–based analysis method. The application of the Health Index showed that 19 transformers (86.36%) were in the Good–Very Good category, while 3 units (13.64%) were in the Caution–Very Poor category. Validation was carried out on samples representing the Very Good, Poor, and Very Poor categories, and it demonstrated strong agreement between the Health Index values and the results of inside check, laboratory tests, as well as operational history and further in-depth testing. Correlation analysis indicated a strong negative relationship between the Health Index and transformer operating age (r = –0.821), suggesting that increasing operation age significantly contributes to a decrease in the Health Index value. Based on the analysis, three follow-up actions are recommended: normal operation, operation with intensive and periodic monitoring, and transformer replacement, representing the overall health levels of the transformers in the study sample.

Downloads

Download data is not yet available.

References

Benhmed, K., Mooman, A., Younes, A., Shaban, K., & El-Hag, A. (2018). Feature Selection For Effective Health Index Diagnoses Of Power Transformers. IEEE Transactions On Power Delivery, 33(6), 3223–3226. Https://Doi.Org/10.1109/TPWRD.2017.2762920

Committee Of The IEEE Power Engineering Society, T. (2006). IEEE Std C57.14-2005, IEEE Guide For The Interpretation Of Gases Generated In Silicone-Immersed Transformers (Vol. 2008, Number February).

Epiwardi, Ruwahyoto, & Heri Sungkowo. (2021). Perencanaan Dan Analisis Kelayakan Investasi Proyek Pemasangan Kapasitor Bank Pada Instalasi Pemanfaatan Energi Listrik. Jurnal Teknik Ilmu Dan Aplikasi, 9(1), 77–82. Https://Doi.Org/10.33795/Jtia.V9i1.16

Fauzan, A., Pharmadita, J., Habibie, A. S., Prayogo, H., Leksono, T. A., Gumilang, H., Purwoko, C., Bimbingan, D. L., Febriandi, F., Pratama, A., & Prasetyo, D. (2024). Pedoman Pemeliharaan Transformator. (0520), 1–145.

Hernanda, I. G. N. S., Mulyana, A. C., Asfani, D. A., Negara, I. M. Y., & Fahmi, D. (2015). Application Of Health Index Method For Transformer Condition Assessment. IEEE Region 10 Annual International Conference, Proceedings/TENCON, 2015-Janua, 0–5. Https://Doi.Org/10.1109/TENCON.2014.7022433

Ipniansyah, I., Bustani, B., Susilo, R. A., Djalil, S., Qomaruddin, Q., & Arbain, A. (2024). Energize Distribution Transformer 1 At Electrical Engineering Workshop State Polytechnic Of Samarinda. International Journal Of Current Science Research And Review, 07(11). Https://Doi.Org/10.47191/Ijcsrr/V7-I11-32

Jahromi, A. N., Piercy, R., Cress, S., Service, J. R. R., & Fan, W. (2009). An Approach To Power Transformer Asset Management Using Health Index. IEEE Electrical Insulation Magazine, 25(2), 20–34. Https://Doi.Org/10.1109/MEI.2009.4802595

Kautsar, A. (2024). 20kv Cubicle Maintenance At PT PLN (Persero) APJ Banten Utara Rayon Prima Krakatau. Fidelity : Jurnal Teknik Elektro, 6(2), 41–48. Https://Doi.Org/10.52005/Fidelity.V6i2.226

Lestari, N., Suwanto, H., & Gunawan, R. (2020). Sistem Pemantauan Kubikel Tegangan Menengah Berbasis Internet Of Things. Infotronik : Jurnal Teknologi Informasi Dan Elektronika, 5(1), 37–42. Https://Doi.Org/10.32897/Infotronik.2020.5.1.5

Muhamad Sadewa, & Endi Permata. (2024). Analisis Desain Kubikel 20kv Untuk Peningkatan Efisiensi Dan Keandalan Sistem Distribusi Listrik. Venus: Jurnal Publikasi Rumpun Ilmu Teknik , 2(6), 116–129. Https://Doi.Org/10.61132/Venus.V2i6.633

Rahmadani, A., Windarko, N. A., & Raharja, L. P. S. (2022). Rancang Bangun Sistem Monitoring Suhu Dan Kelembapan Serta Kendali Dua Heater Pada Kubikel 20 Kv Berbasis Sistem Informasi Geografis. Majalah Ilmiah Teknologi Elektro, 21(2), 219. Https://Doi.Org/10.24843/MITE.2022.V21i02.P09

Rosma, H. I., Ihsan, B., & Pikri, J. (2025). Transformer Health Condition Analysis Based On Health Index And Failure Method. Jurnal Teknik Elektro, 27(2), 121–130. Https://Doi.Org/10.24912/Tesla

Silalahi, D. (N.D.). Dissolved Gas Anomaly In Healthy Transformer Oil : Internal Fault Detection Triggered By Abnormal Operation Noise.

Sirait, J., Nugroho, T. A., & Prayogi, S. (2024a). Studi Analisis Tahanan Isolasi Dan Estimasi Umur Transformator Menggunakan Metode Health Index Di PT PLN (Persero) UPT Cawang. Techno.Com, 23(3), 542–551. Https://Doi.Org/10.62411/Tc.V23i3.10896

Sirait, J., Nugroho, T. A., & Prayogi, S. (2024b). Studi Analisis Tahanan Isolasi Dan Estimasi Umur Transformator Menggunakan Metode Health Index Di PT PLN (Persero) UPT Cawang. Agustus, 23(3), 542–551.

Siswanto, A., Rohman, A., Suprijadi, S., Baehaqi, M., & Arifudin, A. (2022). Analisis Karakteristik Minyak Transformator Menggunakan Pengujian Dissolved Gas Analysis (Dga) Pada Ibt 1 Gardu Induk. Foristek, 12(1), 30–42. Https://Doi.Org/10.54757/Fs.V12i1.142

Tamma, W. R., Prasojo, R. A., & Suwarno. (2021). High Voltage Power Transformer Condition Assessment Considering The Health Index Value And Its Decreasing Rate. High Voltage, 6(2), 314–327. Https://Doi.Org/10.1049/Hve2.12074

Triyatne, Y., & Aribowo, D. (2025). Analisis Keandalan Trafo 2000 Kva Dan Panel Kubikel 20 Kv Melalui Preventive Maintenance PT Surya Toto Indonesia Tbk. JURNAL SURYA TEKNIKA, 12(2), 299–308. Https://Doi.Org/10.37859/Jst.V12i2.10441

Wajid, A., Rehman, A. U., Iqbal, S., Pushkarna, M., Hussain, S. M., Kotb, H., Alharbi, M., & Zaitsev, I. (2023a). Comparative Performance Study Of Dissolved Gas Analysis (DGA) Methods For Identification Of Faults In Power Transformer. International Journal Of Energy Research, 2023. Https://Doi.Org/10.1155/2023/9960743

Wajid, A., Rehman, A. U., Iqbal, S., Pushkarna, M., Hussain, S. M., Kotb, H., Alharbi, M., & Zaitsev, I. (2023b). Comparative Performance Study Of Dissolved Gas Analysis (DGA) Methods For Identification Of Faults In Power Transformer. International Journal Of Energy Research, 2023, 1–14. Https://Doi.Org/10.1155/2023/9960743

Zuroida, A., Galuh Prawetri Citra Handani, Hanifiyah Darna Fidya Amaral, Rohmanita Duanaputri, & Bayu Prasetyo. (2025). Evaluasi Kapasitas Genset Sebagai Sistem Back-Up Energi Listrik Di Gedung Sekretariat Daerah. Elposys: Jurnal Sistem Kelistrikan, 12(1), 37–42. Https://Doi.Org/10.33795/Elposys.V12i1.6837


Bila bermanfaat silahkan share artikel ini

Berikan Komentar Anda terhadap artikel Analisis Kondisi Transformator Tenaga dan Rekomendasi Tindak Lanjut Berbasis Health Index

Dimensions Badge
Article History
Published: 2026-03-31
Abstract View: 168 times
PDF Download: 70 times
Issue
Section
Articles